Pepperl+Fuchs KFA6-SR2-EX1.W 103374 proximity sensor or switch c
Delivery price | 1.00 PLN |
---|---|
Delivery min | 1 |
Delivery time (days) | 7 days days |
Pepperl+Fuchs KFA6-SR2-EX1.W 103374 proximity sensor or switch controls
Pepperl + Fuchs 2 Channel Zener Barrier, ATEX
Pepprl+Fuchs KFA6-SR2-EX2.W (KFA6SR2EX2W)
103373 Pepperl Fuchs - KFA6-SR2-EX2.W
Pepperl+Fuchs KFA6-SR2-Ex1.W Switch Amplifier, 103374
Pepprl+Fuchs KFD2-SR2-EX1.W (KFD2SR2EX1W)
This isolated barrier is used for intrinsic safety applications. It transfers digital signals (NAMUR sensors/mechanical contacts) from a hazardous
area to a safe area.
The proximity sensor or switch controls a form C changeover relay contact for the safe area load. The barrier output changes state when the input
signal changes state. The normal output state can be reversed using switch S1. Switch S3 is used to enable or disable line fault detection of the
field circuit.
During an error condition, relays revert to their de-energized state and LEDs indicate the fault according to NAMUR NE44.
Pepperl+Fuchs Process Automation KFA6-SR2-EX1.W Isolator, Digital, K-System, Switch Amplifier, 1 Channel, 230VAC, 103374
Conductivity switch amplifier KFA6-ER-Ex1.W.LB
1-channel isolated barrier
230 V AC supply
Level sensing input
Adjustable range 1 k and 150 k
Relay contact output
Fault Relay Contact Output
Adjustable time delay up to 10 s
Minimum/Maximum Control
Line fault detection
Function of KFA6-ER-Ex1.W.LB
This isolated barrier is used for intrinsic safety applications. The device generates the AC measuring voltage to the conductive probe.
As soon as the affected Medium to be monitored by the electrodes, the change-over relay contact of the device.
The device is voltage and temperature to stabilize and ensures a defined switching behavior.
The device can be used as on/off control or as a Minimum/ Maximum control. A signal delay can be set in the range between 0.5 s and 10 s.
The device is equipped with a line break monitoring (electricity free Relay in case of error). The line break is indicated by a red LED. By using the line break monitoring the output is used as an error signal output. When disabled, the LB-Monitoring output II follows the output I.
Related products of KFA6-ER-Ex1.W.LB
Matching System Components
K-DUCT-BU
Profile rail
Cable channel in the mounting profile integrated, Safe spatial separation of the Ex and Non-Ex signals, No additional cable guides necessary, standard length 1.8 m, can be shortened, With mounting AIDS
Accessories
KF-ST-5GN
Terminal block
3-pole screw terminal, For KF modules of K-system, packaging unit: 5 pieces, green
KF-ST-5BU
Terminal block
3-pole screw terminal, For KF modules of K-system, packaging unit: 5 pieces, blue
KF-CP
Coding pins
Coding of the K-System-terminal blocks, encoding the LB/FB-System-front sockets, packaging unit: 20 x 6 coding pins
Please contact me get more information
Email:Mia@cwlyautomation.com
VK/Whatsapp/Telegram:+8613667120925
Website: www.cwlyautomation.com