Allen-Bradley 1756-en2tr/1756-EN2TR Communication Modules Popu
odsłony 55
0
osób obserwuje to
Minimalne zamówienie | 1 |
---|---|
Czas dostawy (dni) | 7 days dni |
Allen-Bradley 1756-en2tr/1756-EN2TR Communication Modules Popular products in stock
More models
1756-EN2TR
1756-EN2TP
1756-EN4TR
1756-EN2TRK
1756-EN2TSC
1756-EN3TR
1756-CMS1B1
1756-ENBT
1756-EN2F
1756-CN2R
1756-CNBRK
1756-L55M12
1756-M02AS
1756-RIO
With optical interface No
Supporting protocol for TCP/IP Yes
Supporting protocol for DeviceNet No
Supporting protocol for other bus systems No
Redundancy Yes
IO link master No
Supporting protocol for DeviceNet Safety No
Supporting protocol for EtherNet/IP Yes
Power dissipation 5.1 W
Thermal dissipation 17.4 BTU/h
Enclosure type rating None (open-style)
Ethernet ports 2 Ethernet RJ45 Category 5
CIP unconnected messages 128 + 128 (backplane + Ethernet)
Current draw 1 A @ 5.1V DC, 3 mA @ 24V DC
Ethernet cable 802.3 compliant shielded or unshielded twisted pair
Wiring category 2 - on Ethernet ports, 3 - on USB ports
Communication rate 10/100 Mbps
Connections supported, max TCP: 128, CIP: 256 (CIP connections can be used for all explicit or all implicit applications. for example, a 1756-ENBT module has a total of 128 CIP connections that can be used for any combination of connections.)
Isolation voltage 30V (continuous), Basic Insulation Type, Ethernet to Backplane, USB to Backplane, and USB to Ethernet(Applies only to these modules/series: 1756-EN2T/D, 1756-EN2TR/C,1756-EN3TR/B), Type tested at 980V AC for 60 s
Supporting protocol for LON No
Supporting protocol for ASI No
Supporting protocol for PROFIBUS No
Supporting protocol for CAN No
Supporting protocol for INTERBUS No
Supporting protocol for KNX No
Supporting protocol for Modbus No
Supporting protocol for Data-Highway No
Supporting protocol for SUCONET No
With potential separation No
Supporting protocol for SERCOS No
Supporting protocol for INTERBUS-Safety No
Radio standard Bluetooth No
Radio standard Wi-Fi 802.11 No
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for Foundation Fieldbus No
Supporting protocol for PROFINET CBA No
Supporting protocol for PROFINET IO No
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Radio standard GPRS No
Radio standard GSM No
Radio standard UMTS No
Slot width 1
ATEX temp code T4
For these requirements Select this interface
Control I/O modules and drives
Act as an adapter for I/O on remote EtherNet/IP links
Communicate with other EtherNet/IP devices (messages and HMI)
Bridge EtherNet/IP links to route messages to devices on other networks
1756-EN2F, 1756-EN2FK
1756-EN2T, 1756-EN2TK, 1756-EN2TXT
1756-EN2TP, 1756-EN2TPK, 1756-EN2TPXT
1756-EN2TR, 1756-EN2TRK, 1756-EN2TRXT
1756-EN4TR, 1756-EN4TRK, 1756-EN4TRXT
1756-ENBT, 1756-ENBTK
Support Device Level Ring (DLR) and linear topologies 1756-EN2TR, 1756-EN2TRK, 1756-EN2TRXT
1756-EN3TR, 1756-EN3TRK
1756-EN4TR, 1756-EN4TRK, 1756-EN4TRXT
Support Parallel Redundancy Protocol (PRP) 1756-EN2TP, 1756-EN2TPK, 1756-EN2TPXT
1756-EN4TR(1) , 1756-EN4TRK (1) , 1756-EN4TRXT(1)
(1) 1756-EN4TR supports PRP with revision 4.001 and higher firmware.
Support redundant adapters (2)
(2) Redundant adapters require version 3.x and higher firmware.
1756-EN4TR, 1756-EN4TRK, 1756-EN4TRXT
Provide control in environments where temperatures range from -25...+70 C (-13...+158 F)
1756-EN2TPXT
1756-EN2TRXT
1756-EN2TXT
1756-EN4TRXT
Secure access to a control system from within the plant network 1756-EN4TR, 1756-EN4TRK, 1756-EN4TRXT
Table 1 - ControlLogix EtherNet/IP Connections Specifications (1)
(1) There are 1000 CIP™ I/O connections and 528 CIP messaging connections.
Cat. No. Connections CIP Unconnected Messages
(backplane + Ethernet)TCP CIP (2)
(2) CIP connections can be used for all explicit or all implicit applications. For example, a 1756-ENBT module has a total of 128
CIP connections that can be used for any combination of connections.
1756-ENBT 64 128 64 + 64
1756-EN2F 128 256 128 + 128
1756-EN2T 128 256 128 + 128
1756-EN2TP 128 256 128 + 128
1756-EN2TR 128 256 128 + 128
1756-EN3TR 128 256 128 + 128